Section 09 ELECTRICAL SYSTEM Subsection 06 (TESTING PROCEDURE)
Using jumper wires, connect battery positive post to buzzer positive tabConnect battery negative post to buzzer negative tabSee next photoCAUTION: To avoid buzzer damage, ensure that polarity is respectedA32E3TA

TYPICAL 12-VOLT BATTERY PLUGGED TO BUZZER 1Buzzer positive tab 2Buzzer negative tab

A32E3SA

An intermittent sound should be heardIf not, replace the buzzer with new one
TYPICAL 12-VOLT BATTERY PLUGGED TO BUZZER 1Buzzer positive tab 2Buzzer negative tab