Section 06 ELECTRICAL Subsection 04 (BATTERY)
INSTALLATION OF BATTERY
A00E0DA

Charger Rheostat 12 50 Ammeter Battery

Ensure vent tube is properly installed on battery elbowConnect vent tube to vehicle fitting on front frameRoute RED positive cable behind retaining strip and connect it to positive battery terminalConnect RED wire (coming from ignition switch)Connect BLACK negative cable LASTCAUTION: Negative battery terminal should always be disconnected FIRST and reconnected LASTApply silicone dielectric grease (PN 293 550 004) on battery posts and connectors1

For service application and permanent installation, both ammeter and rheostat can be built into small box adjacent to your chargerCAUTION: Adequate ventilation MUST be provided to cool the rheostat