ELECTRICAL Load Test
NOTE: This test can only be performed on machines equipped with electric startThis test cannot be performed if the engine or starting system is not working properlyA battery may indicate fully charge condition on the OCV test and the specific gravity test, but still not have the storage capacity necessary to properly function in the electrical systemFor this reason, battery capacity or load test should be conducted whenever poor battery performance is encounteredTo perform the test, hook multitester to the battery in the same manner as in the OCV testThe reading should be 12.6 volts or greaterEngage the electric starter and view the registered battery voltage while cranking the engineContinue the test for 15 secondsDuring this cranking period, the observed voltage should not drop below 9.5 voltsIf the beginning voltage is 12.6 or higher and the cranking voltage drops below 9.5 volts during the test, replace the battery
Refilling Low Battery