2007 Arctic Cat Four-Stroke Factory Service Manual, Page 211Get this manual

2007 Arctic Cat Four-Stroke Factory Service Manual, Page 211

TESTING COMPONENTS ! NOTE: Resistance tests of the engine electrical components should be made using the Fluke Multimeter onlyReplace any component that does not have test value within specifications
2Reverse the tester probes and repeat the testTake note of which terminals register continuity! NOTE: Continuity should register in only one directionIf there is continuity in the reverse direction on any of the terminals, replace the rectifier
Rectifier (Positive Test)

1Using an ohmmeter, connect the positive tester probe to the terminal and the negative tester probe to each of the rectifier terminalsTake note of which rectifier terminals register continuity2Reverse the tester probes and repeat the testTake note of which terminals register continuity! NOTE: Continuity should register in only one directionIf there is continuity in the reverse direction on any of the terminals, replace the rectifier