2007 Arctic Cat Four-Stroke Factory Service Manual, Page 201Get this manual

2007 Arctic Cat Four-Stroke Factory Service Manual, Page 201

! NOTE: On the 1100 cc Z1, it is necessary to install the air silencerProceed to Servicing Air Silencer (1100 cc Z1) sub-section in Section and follow steps 3-12 of INSTALLING If battery voltage is present at the plug-in and the starter fails to activate, use the following procedure: 1With the ignition switch plugged in, place the emergency stop switch to the OFF position2Connect the red tester lead to the blackyellow wire; then connect the black tester lead to suitable ground3Rotate the key to the START position and verify battery voltage! NOTE: If no battery voltage is present, troubleshoot the harness andor the starter solenoid
Ignition Switch Electric Start Function
(660 cc1100 cc Z1) TESTING RESISTANCE

! CAUTION
To prevent ohmmeter damage when testing circuits on snowmobiles equipped with an electric start, be sure to disconnect the battery before testing
Emergency Stop Switch
(660 cc1100 cc Z1) RESISTANCE

1Disconnect the wiring harness from the ignition switch; then remove the switch from the console2Using the ohmmeter, test the connections indicated in the following chartIf the meter reads more than one ohm of resistance, the switch must be replacedTest #