23Connect the air bypass hose to the bypass valve on the turboSecure with the two clamps
2Remove the two torx-head cap screws (A) securing the console to the chassis; then lift up the rearward end of the console and disconnect the console harness plug-inRemove the console

24Fill the coolant system with engine coolant (see appropriate Liquid Cooling System in this section)25After the cooling system has been properly filled, connect the negative battery cable and start the engine; then inspect for any coolant leaks