Bombardier SeaDoo 2001 factory shop manual, Page 273Get this manual

Bombardier SeaDoo 2001 factory shop manual, Page 273

Section 06 ENGINE MANAGEMENT (DI) Subsection 04 (DIAGNOSTIC PROCEDURES)
NORMAL OPERATION RESUMES IF FAULT REMOVED AND
FAULT DETECTED WHILE ENGINE RUNNING

FAULT DETECTED WHILE ENGINE NOT RUNNING

DIAGNOSED COMPONENT SENSORCIRCUIT

ECU INTERNAL NAME

FAULT CODE

FAULT DETECTED

SERVICE ACTION AND POSSIBLE CAUSES

Battery voltage

BV_HI_RED

Battery voltage very high

Full resetKey off and on

Possible causes: Battery failure, rectifier failure, battery terminal connectionService action: Check fuseCheck system circuits 3-25 to batteryterminal, 2-26 to regulator pin connector pin A, 2-25 to regulator pin connector pin BPossible causes: Battery failure, rectifier failure, damaged circuit wires, battery terminal connection, damaged magneto, damaged connectorsService action: Check fuse, check system circuits 3-25 to batteryterminal, 2-26 to regulator pin connector pin A, 2-25 to regulator pin connector pin BPossible causes: Battery failure, rectifier failure, damaged circuit wires, battery terminal connection, damaged magneto, damaged connectorsService action: Check for shorts to ground or corrosion on the following system circuits 3-10 or 3-3Possible causes: Damaged circuit wires, associated sensor failure (TPI or MAP), ECU faultService action: Check for shorts to ground or corrosion on system circuit 4-18