Bombardier SeaDoo 2001 factory shop manual, Page 93Get this manual

Bombardier SeaDoo 2001 factory shop manual, Page 93

Section 04 ENGINE Subsection 04 (MAGNETO SYSTEM)
Magneto Housing
To remove magneto housing no5, starter has to be removedRefer to STARTING SYSTEMUnscrew retaining screws, then withdraw housing
Battery Charging Coil
To replace battery charging coil no7: Heat the armature plate to 93C (200F) around the screw holes to break the threadlocker bond
Generating Coil
To replace generating coil no6: Heat the armature plate to 93C (200F) around the screw holes to break the threadlocker bondF00D09A

1Heat the armature plate