Section 02 MAINTENANCE Subsection 05 (STORAGE)
Hose Disconnection Disconnect water INLET hose at engine between Tfitting and cylinder head fitting
F07E0NB
GTX DI MODELS 1Water outlet hose
F12E0BA
1Disconnect this side of the T-fitting
Temporarily install short piece of hose to replace the one removedAntifreeze Insert funnel into the temporary hose and pour antifreeze mix in engine until the colored solution appears at cooling system bleed outlet