Section 05 ENGINE MANAGEMENT (DI) Subsection 04 (DIAGNOSTIC PROCEDURES)
TPS "OUT OF RANGE" Fault It is caused by the sensor reading going out of its allowable rangeThis fault can occur during the whole range of movement of the throttleTo diagnose this fully, it is recommended to operate the throttle through its full rangeIt is also recommended to release the throttle quickly as this may also show up fault that is intermittentPOSSIBLE CAUSES Check if wrong connector is connected to TPS Check if sensor is loose Inspect sensor for damage or corrosion Inspect wiring (voltage test) Inspect wiring and sensor (resistance test) Test sensor operation (wear test) RESULT Yes Yes Yes Failed Fix Fix and reset closed TPS Replace and reset closed TPS Repair If bad wiring, repair If bad TPS, replace and reset closed TPS Replace and reset closed TPSACTION