Section 08 ELECTRICAL SYSTEM Subsection 06 (DIGITALLY ENCODED SECURITY SYSTEM)
Basic Self-Diagnostic Mode
It is self-activated when the safety lanyard cap is being installed on the watercraft switchIt gives immediate monitoringSome codes may occur only when pressing the startstop buttonRefer to the following chartSIGNAL short beeps (while installing safety lanyard on watercraft switch) long beep (while installing safety lanyard on watercraft switch or when pressing startstop button) CAUSE Safety lanyard is recognized by the MPEMREMEDY Ignition is authorized, engine can start