Section 07 ELECTRICAL SYSTEM Sub-Section 02 (IGNITION SYSTEM)
All Other Models 1Remove the female spade connectors from the primary side of the ignition coil2With the meter set on the resistance scale, connect the meter leads to the primary terminals of the coil3Resistance should be between 0.340.62 ohmSecondary Winding The spark plug caps must be removed from high tension cables, because they are resistor capsThe cap resistance is 4.48 ohms2Connect Bombardier Ignition Tester probes then set switch and dial as follows:
Tester probe Component Tester adapter (paper clip) on spark plug cable Grounding device Tester switch position Tester dial position

IGNITION TESTER
30 20 10 70 80 90

A00E0QA

O-SPECIALT