Section 08 ELECTRICAL SYSTEM Sub-Section 06 (DIGITALLY ENCODED SECURITY SYSTEM)
Basic Self-Diagnostic Mode
It is self-activated when the safety lanyard is being installed on the watercraft switchIt gives immediate monitoringSome codes may occur only when pressing the startstop buttonRefer to the following chartSIGNAL short beeps (while installing safety lanyard on watercraft switch) long beep (while installing safety lanyard on watercraft switch or when pressing startstop button in some cases) CAUSE REMEDY

Everything is correct with the safety lanyard (good contact and right lanyard cap) Bad connection between saafety lanyard cap and switch Wrong safety lanyard