Bombardier SeaDoo 1992 factory shop manual, Page 164Get this manual

Bombardier SeaDoo 1992 factory shop manual, Page 164

Section 07 ELECTRICAL Sub-section 06 (CDI AND CHARGING SYSTEMS)
Voltage Test

Proceed as follows :
- Start engine- Connect voltmeter (set on DC volt scale) on battery

posts- Bring engineto approximately

5500 RPM
If voltmeter reads over 15 volts, regulator is defectiveReplace it
NOTEWhatever the voltmeter type used (peak voltage or RMSI, the voltage must not exceed 15 VA faulty regulator will allow voltage to exceed 15 as engine speed is increasedCAUTIONDuring this test the battery cables must be reconnected the battery
Charging System Relay
The relay is located on multi-purpose electronic module near the sideIf the system is not charging the battery, the relay could be the problem
Magneto, Battery Charging Coil
With BombardierIgnition Tester Operate it as for ignition system verifications