Electrical Systems Fuel Level Switch Testing
1Set multimeter to ohms2With the fuel sender removed from tank, insert probes into PINK and BLK pinsResistance Specifications: Full33 OHMS Empty240 OHMS 3Reinstall fuel pumpTighten collar to 36 44ftlbs(50 61 Nm)Use special tool: PN 2872621
FUEL LEVEL SENDER

Paddle Wheel Testing
1Set multimeter to ohms2Insert probes into sensor connectorSpin paddlewheelMeter readings should rapidly cycle between resistance and O.L