2001 Polaris SLX, PRO 1200, Virage TX, Genesis, Virage TXi, Genesis i Personal Watercraft Service Manual, Page 262Get this manual

2001 Polaris SLX, PRO 1200, Virage TX, Genesis, Virage TXi, Genesis i Personal Watercraft Service Manual, Page 262

Electrical Systems 2001 RPM Limiter Systems Model
Genesis Genesis Virage TXi Virage PRO 1200 SLX

Temperature Sensor "ON" (FoCO)
1800 114 180"8 114 180 114 2378 114 23r8114 2378 114 C
MFDMFI Display
OilHeatFuel OilHeatFuel OilHeatFuel OilHeatFuel OilHeatFuel OilHeatFuel

RPM Limit
OverheatS.L.O.W3500 RPM Overheat3500RPM OverheatS.L.O.W3500 RPM Overheat3500RPM Overheat3500RPM Overheat3500RPM

RPM Limiter Function
If the engine overheats, the thermal switch becomes conductive and provides ground path for the tan wire leading from the COl module and the Multi-Function DisplayThe Multi-Function Display will display "HOT" warning message, the warning light will flash, and the engine RPM will be limited to approximately 3500 RPMA circuit within the COl senses the ground path connection and activates the limiting functionSee diagram belowImportant Note: When the engine overheat circuit has caused the system to limit, it will continue to limit until both of the following conditions are met: 12The problem that caused the initial limiting must be corrected (cool engine); The operator must momentarily release the throttle and allow the RPM to fall below 3500