Final DrivePropulsion 2001 Pump AssemblyExploded ViewSLX PRO 1200 Virage TX Virage TXi

Pump Assembly Notes:
A Pump must be flush against hull to prevent leakage or cavitationApply liberal amount of marine grade silicone to mounting O-ringS Install seals with lip toward impellerC 'Orifice size in water supply pipes are different depending on modelVerify proper orifICe size if pipe is replacedE 18ft.1bs(25Nm) Apply Loctite "" 242 to threadsF 28ft.lbs(39Nm) Apply anti-seize lubricantG Thicker edge on bottom of pump assemblyH Apply Polaris All-Season greaseI Sacrificial Anode Torque: 25 in.lbs(2.9Nm)Apply Nyogel to threadsTorques: 18 ft.lbs(2SNm) Apply Loctite