2001 Polaris SLX, PRO 1200, Virage TX, Genesis, Virage TXi, Genesis i Personal Watercraft Service Manual, Page 50Get this manual

2001 Polaris SLX, PRO 1200, Virage TX, Genesis, Virage TXi, Genesis i Personal Watercraft Service Manual, Page 50

Maintenance EngineContinued ThermostatPop Off Valve Cleaning
If low end performance of the watercraft begins to deteriorate, and the jet pump intake area is free of debris and weeds; or if the overheat alarm sounds, the thermostat pop off assembly should be checked for debris and cleanedInspect the thermostat pop off assembly if the watercraft has been stored for more than 30 days or has been used in salt water
Note the location of all parts when cleaning the thermostatpopoff valve assemblyBe sure all parts are positioned correctly during reassembly, or severe engine damage will result within very short period of operationDo not perform this maintenance while the watercraft is in the waterThe thermostat pop off assembly is under tension from an internal springWhen the screws are removed, the assembly will come apart quickly if not held together firmly1Using 316" (.5 cm) hexagonal wrench and flat screwdriver, remove screws while holding thermostat pop off assembly firmly togetherCarefully take assembly apartBe careful not to lose any parts2Inspect thermostat pop off assembly for debris, such as sand or seaweed, and clean thoroughly with waterInspect pop off valve for wearSee III13Inspect condition of gaskets and rubber partsReplace any parts that appear cracked, damaged, or distortedIII1