FFI1M FUEL INJECTION Diagnostic Guide

ENGINE CRANKS BUT WON'T START
SYSTEMCOMPONENT Fuel System CAUSES Water in fuel tankno fuel Restricted or leaking fuel delivery systern OldStale Fuel Circuit Breaker Open to Fuel Pump ACTIONS Inspect fuel tank for waterCheck for damaged fuel linesSubstitute known good fuel Fuel pump should run for 10 seconds when tether cord is connected to stop switchPush reset button on breakerSee Action StepsFuel System check fuel pump, Crank Position Sensor Monitor injector wires while cranking or use FFI1M Diagnostic Software to activate injectorsSee Action Steps Fuel System Test andor replace switch, (BlackYellow wires) Test with Ohmmeter FFI1M Diagnostics Software should indicate at least 200 RPM while crankingUse PRV to measure voltage at coils180 volts minimum See Action StepsIgnition System to test stop circuit See Action StepsIgnition System to test stop circuit See Action StepsIgnition System Low or inadequate battery, loose connection, bad starter, etcSee Engine section