ELECTRICAL Starter Motor
Brush Replacement
1Remove terminal nut with lock washer, flat washer, large phenolic washer, small phenolic spacers, and sealing O-ringInspect O-ring and replace if damagedSlide positive brush springs to the side, pull brushes out of their guides and remove brush plateCleaning

Some cleaning solvents may damage the insulation in the starterCare should be exercised when selecting an appropriate solventIf the commutator needs cleaning use only an electrical contact cleaner