2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 190Get this manual
http:ReadManm
FINAL DRIVEJET PUMPBILGE SYSTEM Pump Alignment Inspection
Pump Alignment Inspection, Cont
Symptoms
Probable Cause
Repair Required
Shim engine mounts Tighten or replace mounts Tighten engine to mounting plate bolts
Splines worn or stripped at engine Engine misaligned to pump coupler end of drive shaft or inside Loose or broken engine mounts of coupler; Engine loose on mount plate through-hull fitting failure or rapid wear of bushings in bearing housingSplines worn or stripped at impeller end of drive shaft or inside impellerPump mounting bolts loose Pump misaligned with hull (check for gap between hull and pump housing as shown on Page