ELECTRICAL Ignition System TestingPVL PVL Ignition Troubleshooting, ContBIf the readings are still out of range, open the electrical box and remove the plug wire(s) that are showing incorrect readingsaMeasure the resistance of the plug wire(s)
Plug wire

b.Check the resistance of the coil without the plug wires installed
Ignition Coil
(do not disconnect the primary side of the coil)

C.lf all three plug wires show open, remove plug caps and recheck continuity from center conductor of plug wires to engine groundIf still bad, open box and check coil ground path
III4 2Open the electrical box and check for correct connections between the stator, CDI, coils, and terminal boardInspect the wiring for incorrect connections or physical damageA.Verify the correct installation of the Yellow stator wire and YellowPurple jumper wire if so equippedaDisconnect the stator from the electrical box (within the electrical box)bConnect the negative test lead of the ohm meter to the black wire coming from the stator and leave it connected for the duration of test 2cConnect the positive test lead to an engine ground