1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 251Get this manual

1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 251

FINAL DRIVEJET PUMPBILGE SYSTEM Pump Housing Installation Pump Housing Installation

Review important information regarding pump stud installation on page 5.27 and 5.28 before proceeding with pump housing installation! 1Liberally grease large pump-to-hull O-ring and apply Marine Grade Silicone sealant to O-rings on bilge siphon and cooling water supply fittingsApply anti-seize to threads of pump mounting studsInstall pump housing and hold inward against hull