1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 237Get this manual

1999 Polaris SLH, SLTH, SLX, SLTX, PRO785 Factory Service Manual, Page 237

FINAL DRIVEJET PUMPBILGE SYSTEM
Pump Intake
1999 SLTH SLTX

Use Marine Grade Silicone Sealant (PN 8560054)Allow sealant to cure for 24 hrsbefore operating craft
Apply Marine Grease To O-ring

IMPORTANT!
Apply continuous 12" (1 .3 cm) bead of Marine Grade Silicone Sealant to all mating surfaces of the hull and scoopClean excess silicone after installationNOTE: Replace inlet scoop if damaged or bentCavitation may result if silicone is not continuously appliedA pin hole leak may cause enough cavitation to damage stator and impellerAllow 24 hours to cure