ELECTRICAL Ignition System TestingGenesis X-45 PVL Ignition Troubleshooting, Cantd.Connect the positive test lead to the purple
Stator Purple Wire

Stator Black

SPECIFICATION: 5.5 ohms

eConnect the positive meter lead to the follow ing wires (one at time)

RedPurple and Gray wre (one al time)

SPECIFICATIONS: REDPURPLE: GRAY: OPEN OPEN

Open readings are correct for Tektronix DMM 155 meterOther meters may