FINAL DRIVEJET PUMPBILGE SYSTEM
Pump Intake
1999 Genesis Genesis FICHT

Use Marine Grade Silicone Sealant (PN 8560054)Allow sealant to cure for 24 hrsbefore operating craft
IMPORTANT!
Apply continuous 12" (1.3 cm) bead of Marine Grade Silicone Sealant between hullpump housing and on O-ringClean excess silicone after installation
IMPORTANT!
Apply continuous 12" (1 .3 cm) bead of Marine Grade Silicone Sealant between hullscoop edgesClean excess silicone after installationNOTE: If inlet scoop is damaged or bent during removal, replace with new scoop