MAINTENANCEfTUNE UP Cable Adjustments Alternate Method Of Measuring Nozzle
Following is an alternate method for checking nozzle centering
Rear View Of Pump Nozzle

Pertorm steps and on page 2.23 to center
handlebarsMeasure distance from rear-most edge of steering nozzle (or trim nozzle) to stationary pump nozzle (extension housing) with 6" steel rule or vernier caliperMeasure at the same point on both left and

right sides along horizontal center linedistance should be equalSee Ill1

Measure on horizontal center line from rear of steering or trim nozzle to stationary nozzleDistance should be equal