2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 419Get this manual

2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 419

BACK-UP VOLTAGE LINE Remove the front storage box (page 3-5)Release the wire bandDisconnect the combination meter 10P (Gray) connectorBAND

10P (Gray) CONNECTOR Measure the voltage between the BlacWwhite (+) and Green (-) wire terminalsThere should be battery voltage at all timesIf there is no voltage, check the following: open circuit in the Blacktwhite wire between the combination meter connector and METER fuseblown METER fuse (5 A)open circuit in the Redblue wire between METER fuse and main fuseblown main fuse (30 A)open circuit in the Red wire between the main fuse and battery Green COMBINATION METER 10P (Gray) CONNECTOR (Wire sidelfemale terminal)

POWER INPUT LINE
Remove the front storage box (page 3-5)Release the wire bandDisconnect the combination meter 10P (Gray) connectorBAND