2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 385Get this manual
BATTERYKHARGING SYSTEM
TROUBLESHOOTING
BATTERY IS DAMAGED OR WEAK BATTERY TEST Remove the battery (page 16-61 Check the battery condition using the recommended battery tester RECOMMENDED BATTERY TESTER: Micro 404 XL (U.S.Aonly)
Is the battery in good condition?
- GOTOSTEP2- Faulty battery
2, CURRENT LEAKAGE TEST
Install the battery (page 16-6)Check the battery current leakage test (Leak test; page 16-71Is the current leakage below mA?
- GO TO STEP 4
- GO TO STEP 3
3CURRENT LEAKAGE TEST WITHOUT REGULATORIRECTIFIER CONNECTOR
Disconnect the regulatorlrectifier connector and recheck the battery current leakageIs the current leakage below mA?
- Faulty regulatorlrectifier-
Shorted wire harness Faulty engine stop switch