2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 326Get this manual

2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 326

EXHAUST SYSTEMJTURBOCHARGER CLEANING AND INSPECTION Remove the carbon deposits from the exhaust pipe to clean itFlush the water passages in the exhaust pipe with pressurized fresh water to remove any foreign materialCheck the water passages for corrosionCheck the mating surfaces for nicks or other damage
EXHAUST PIPE

WASTEGATE VALVE INSPECTION
Refer to page 8-44 for wastegate actuator operation checkDo not remove the Check the wastegate valve for proper seating, withactuator from the out play in the valve and valve armturbocharger

ACTUATOR WASTEGATE VALVE