FUEL SYSTEM (Programmed Fuel Injection) 4TCP Sensor Output Voltage Inspection

Pull the safety lanyard lock clip off of the engine stop switchDisconnect the TCP sensor 3P connectorInsert the safety lanyard lock clip in engine stop switchMeasure the voltage between the wire harness side connector terminalsConnection: Bluewhite(+)Ground (-) Is the voltage within 4.75 5.25 V? YES NO

TCP SENSOR 3P (Black) CONNECTOR (Wire sidelfemale terminal)
- Faulty TCP sensor
- GO TO STEP 5
Bluelwhite

5TCP Sensor Output Line Short Circuit Inspection