COOLING SYSTEM

THE WARNING BUZZER SOUNDED AND THE ENGINE STOPPED IMMEDIATELY (EXHAUST COOLING SYSTEM)
1Water strainer screen Remove the jet nozzle (page 14-7) and check the water strainer screen
Is the water strainer screen clogged? YES NO

- Clean the water strainer screen- GO TO STEP 2
WATER STRAINER
SCREEN 2Cooling water hose damage check Remove the side panels (page 3-7)Flush the system (page 5-3)

Is there any damage in the water hoses or is the water hose disconnected? YES

- Repair the damage
3Pilot water nozzle (flushing check)

Flush the system and check the pilot water nozzle (page 4-16)
Is the water running from the water nozzle?

GO TO STEP 4way valve and exhaust manifold
- The system is clogged between the one-