2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 106Get this manual

2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 106

FLUSHING AND STORAGE- 10.Check the fire extinguisher is not beyond its expiration date and charge or replace, if necessary11.Install the following:

- body panel (page 3-3)
- seats (page 3-5)

IF THE WATERCRAFT IS SUBMERGED
If the watercraft is submerged or flooded with water, act quickly to avoid severe damage
URGENT PROCEDURE AFTER REMOVING WATERCRAFT FROM THE WATER
The watercraft must be serviced immediately using the following procedureIf not, it will cause severe engine damageRemove the bilge drain plugs to drain the water out of the engine compartmentRemove all the spark plugs and insert shop towels into the spark plug holesDisconnect all the fuel injector connectorsOpen the throttle fullyPress the starter switch to crank the engine for 15 secondsContinue this procedure until the water stops coming out6Remove the shop towels and pour tablespoon of clean engine oil into each cylinder through the spark plug hole7Cover the spark plug holes with shop towel8Push the starter switch several times crank the engine and distribute the oil