2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 102Get this manual

2008 Honda Aquatrax ARX1500T3/T3D factory service manual, Page 102

SERVICE INFORMATION GENERAL
IMPORTANT SAFETY PRECAUTIONS Flushing must be performed in well ventilated areaNever run the engine in an enclosed areaThe exhaust contains poisonous carbon monoxide gas that may cause loss of consciousness and lead to death Keep hands, feet, and loose clothing away from the jet pump when running the engineNever touch any electrical partsDo not turn over the engine when cleaning the jet pump areaRemove the safety lanyard and disconnect the negative battery cable to prevent accidental engine startingTHE IMPORTANCE OF FLUSHING Flushing the cooling system with fresh water is essential to neutralize corroding effects of salt or other chemical products present in waterThe flushing water will help flush out any sand, salt, shells or other particles in water jackets (engine, exhaust components, turbocharger) andor hosesClean the watercraft thoroughly and flush the cooling system with only fresh water after each use, or before storageAlso, use the flushing procedure to provide engine cooling when running the engine out of the water for service purposesA flush connector fitting (flushing connector) is located near the reverse bucket to attach garden hose for flushing