2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 451Get this manual

2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 451

ELECTRIC STARTER
TROUBLESHOOTING
Starter motor does not turn 1Fuse Inspection Check for blown main fuse (30 A) or sub-fuse (5 A)Is the fuse blown? YES NO Replace the fuse GO TO STEP 2
2Battery Inspection Check that the battery is fully charged and in good conditionIs the battery in good condition? YES NO Charge the battery (page 16-6) GO TO STEP 3
3Starter Relay Switch Operation Inspection Check the operation of the starter relay switch (page 18-12)Does the starter relay switch click? YES NO GO TO STEP GO TO STEP 5
4Starter Motor Inspection Remove the safety lanyard switch from the engine stop switchApply battery voltage to the starter motor directlyDoes the starter motor turn? YES NO Poorly connected starter motor cable Faulty starter relay switch Faulty starter motor (page 18-6)