2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 278Get this manual

2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 278

COOLING SYSTEM 7Cooling water passage (inlet section) Check for clogs between the jet pump and oneway valveIs the system clogged between the jet pump and one-way valve? NO YES Clean or replace the faulty part Check the exhaust cooling system (page 7-5)
THE WARNING BUZZER SOUNDED AND THE ENGINE SPEED DID NOT RISE ABOVE APPROX3,000 rpm, THEN THE ENGINE STOPPED 1Cooling water filter Remove the jet nozzle (page 14-8) and check the water filterIs the water filter clogged? YES NO Clean the water filter GO TO STEP 2WATER FILTER