2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 211Get this manual

2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 211

FUEL SYSTEM (Programmed Fuel Injection) 5TP Sensor Output Line Short Circuit Inspection Check for continuity between the TP sensor 3P connector terminal of the wire harness side and groundConnection: Light green Ground Is there continuity? YES NO Short circuit in the Light green wire GO TO STEP 6TP SENSOR 3P GRAY CONNECTOR (viewed from the terminal side)