2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 141Get this manual

2004-2007 Honda Aquatrax ARX1200N3/T3/T3D Factory Service Manual, Page 141

LUBRICATION SYSTEM
OIL PRESSURE INSPECTION
Remove the seats (page 3-4)If the engine is cold, the oil pressure reading will be abnormally highStart the engine according to the flushing procedure (page 5-2)Let the engine idle for minutesIf the air temperature is below 10!C (50!F), let the engine idle for an additional minutes (a total of 10 minutes)Turn off the water, rev the engine for about 15 seconds to clear water out of the exhaust system, and pull the safety lanyard clip off of the engine stop switchCheck the oil level and add the recommended engine oil if necessary (page 4-12)Slide the boot off the low oil pressure switchDisconnect the low oil pressure switch connectorRemove the low oil pressure switch and connect an oil pressure gauge attachment and gauge to the oil pressure switch holeTOOLS: Oil pressure gauge set PRESSURE GAUGE ATTACHMENT BOOT CONNECTOR

OIL PRESSURE SWITCH

Oil pressure gauge attachment