Suzuki outboard motors 1988 2003 repair manual., Page 348

10-6 REMOTE CONTROL 2Disconnect the engine stop switch wiring harness3Remove any wire straps that connect the switch to the box4Remove the switch attaching nut, 5Remove the switch from the control boxTo install: 6Install the switch in the control box7Install the switch attaching nut and tighten securely8Install any wire straps that connect the switch to the control box9Connect the engine stop switch wiring harness10Test the switch for proper operation11Install the control box side covers and mount the control box in the boatTESTING
Fig10 Here is the complete switch assembly (switch and lanyard) after being removed from the control box
ISee Figure 12
1Disconnect the trimltilt switch wiring harness2Connect multimeter between the switch harness terminals as illustrated3With the switch in the stated positions, check for continuity between the various terminals4If the switch functions properly, there may be problem in the powerhead wirina harness5 If the switch does not function as specified, the switch may be faulty10Test the switch for proper operation11Instal! the control box side covers and mount the control box in the boatTESTING
ISee Figure 11