Suzuki DF200/DF225/DF250 V6 4-Stroke Outboards Service Manual, Page 142Get this manual

Suzuki DF200/DF225/DF250 V6 4-Stroke Outboards Service Manual, Page 142

ELECTRICAL

TROUBLESHOOTING
NOTE: Before troubleshooting the electric starter system, make sure of the following: Battery is fully charged All cableswires are securely connected Shift is in "NEUTRAL" position Emergency stop switch lock plate is set in place& If any abnormality is found, immediately disconnect battery cables from batteryEngine does not start
Does engine turn over with continued cranking?

Does starter motor rotate?

Check battery for charging condition Check battery terminals for connections and corrosion Check main (60 A) andor sub (30 A) fusecase(See page 4-3 YES YES YES Check for starter relay "Click" sound when turning ignition switch to "START"Is there "Click" sound?

Check ECM-No1 terminal voltage(See page 3-49 YES Check function of neutral switch(See page 4-11 Check emergency stop switch function(See page 4-12 Check ignition switch function(See page 4-10 Check starter relay(See page 4-10 Check wiring system and connections between starter relay and ignition switch