PERIODIC MAINTENANCE

6Install shimIdentification number should face down (towards tappet)7Rotate crankshaft to be open (lift up) valve8Remove tappet holder and tighten camshaft housing bolts to specified torque" Camshaft housing bolt: 12 Nm (1.2 kg-m, 8.7 lb-ft)
Special tool Tappet Camshaft