Suzuki 2003-2007 DF60 DF70 Outboard Motors Service Manual, Page 104Get this manual

Suzuki 2003-2007 DF60 DF70 Outboard Motors Service Manual, Page 104

ELECTRICAL

INSPECTION
BATTERY CHARGE COIL 09930-99320: Digital tester Tester range: (Resistance) 1Disconnect the battery charge coil wire from the rectifierregulator2Measure resistance between the terminals for all combinationsBattery charge coil resistance: Terminal for tester probe connection Yellow to Yellow Yellow to Yellow Yellow to Yellow Resistance 0.3 0.5 0.3 0.5 0.3 0.5

If the measurement is out of the specification, replace the battery charge coilRECTIFIERREGULATOR 09930-99320: Digital tester Tester range: (Resistance) 1Disconnect all wires of the rectifierregulator2Measure resistance between the terminals for all combinationsNOTE: The values given below are for the SUZUKI digital testerAs thyristors, diodes, etcare used inside this rectifierregulator, the resistance values will differ when an ohmmeter other than the SUZUKI digital tester is usedRectifierregulator resistance: Tester probe(Red) Black Tester probe(Black) Black White Yellow1 Yellow2 Yellow3