39Remove bolts from voltage regulator and remove voltage regulator from exhaust coverRemove 17 bolts from exhaust cover and remove exhaust cover and ignition coils as an assemblyNOTE: Ignition coils may be removed individually by removing boltsNOTE: Rubber mallet may be used to break gasket adhesion between cover and block 40Remove allen screws from stator