Troubleshooting the "Up" Circuit (When "Down" Circuit Is OK) Remote Control NOT Equipped with Trailer Button

Connect Voltmeter red lead to Point and black lead to ground Depress the "Up" trim button
Battery Voltage Indicated: Connect Voltmeter red lead to Point 3
No Voltage Indicated: Connect Voltmeter red lead to Point and black lead to ground DepressDown" trim buttonIf battery voltage is indicated, wire is open between Points and 8
Battery Voltage Indicated: Connect Voltmeter red lead to Point Depress "Up" trim button