1988-1992 Mercury Force 5HP Outboards Service Manual, Page 103

2 Remove screw (A)Remove coil and condenser lead wires from breaker point terminal (8) and remove breaker points (C)PINSTALLING BREAKER POINTS
1Position breaker pOints on stator plate2.Install screw (A)NOTE: Do not tighten screw (A)
3Connect condenser and coil leads to
breaker point terminal (8)Check cam wiper felt (C) for sufficient lubricant by squeezing between fingersIf dry, work small amount of lubricant (Special Tool NoT-2961) into felt with fingers