1984-1986 Mercury Force 9.9 and 15HP Outboards Service Manual, Page 32Get this manual

1984-1986 Mercury Force 9.9 and 15HP Outboards Service Manual, Page 32

Te.t Conden.er SerleRe.l,tance1Place selector knob inCONDENSER SERIES RESISTANCEposition 2Clip the small black test lead and the small red test lead togetherTurn meter set knob until meter pointer lines up with set scales on ight-hand side of meterDisconnect leadsThis wil set the meter3Connectsmall red test lead to condenser lead4Connect small black test lead to condenser body 5Meter must remain in the green area on the righthand side 01 theCONDENSER SERIES RESISTANCEscale 6If meter pointer moves to the red area, series resistance is poorReplace condenser7Disconnect tester leads and unplug the testerIn.tallatlonConden.er:Install condenser on stator plate and secure with screw as shown Figure 72Connect condenser lead ire to terminal block of breaker po int3'nstalll'ywheel RemovalColi from .tator plate: