Conden.er Capacity Te.t1Plug tester into 115-voll60 cycleACoutlet2Turn selector knob toCONDENSER CAPACITY" positionFigure 4 3Turn selector knob toOFF': Remove tester leads and teslcondenser series resistance
Conden Serl Ince Tt1Place selector knob inCONDENSER SER IES RESISTANCE" position SELECTOR KNOB

2Clip the small black test lead and the small red test lead togetherTurn meter set knob until meier pointer lines up with set scales on right-hand ide of meterDisconnect leadsThis sets the meter3Connect small red lest lead to consenser lead4Connect small black test lead 10 condenser body5Meter must remain in the green area on the righthand side 01 the "CONDENSER SER IES RESISTANCE" scale6II meter pointer moves to the red area, series resistance is poorReplace condenser7Disconnect tester leads and unplug the tester
RED TEST LEAD

CONDENSER LEAO