ELECTRICAL AND IGNITION CHARGING SYSTEM TESTS Start and run the outboard at approximately 5000 RPMUse the variable load tester to draw the battery down at rate equivalent to the stator's full output The ammeter should indicate nearly full output, Approximately 25 5000 RPMDecrease the battery load toward Ammeter should show reduced outputAs the current draw decreases, the battery voltage should stabilize at approximately 14.5 If results vary, check stator BEFORE replacing the EMMSee STATOR TESTS on p113
1J2 connector