2006 SD Johnson 4 Stroke 9.9-15HP Outboards Service Manual, Page 89Get this manual

2006 SD Johnson 4 Stroke 9.9-15HP Outboards Service Manual, Page 89

ELECTRICAL ELECTRIC STARTER SYSTEM Check for continuity across magnetic switch "S" terminal and "M" terminalIf no continuity, replace coilPlace plunger against flat surface and push the magnetic switch downWith switch held down, check for continuity between terminal "8" and terminal"M If no continuity, replace the magnetic switch and! or plunger