2006 SD Johnson 4 Stroke 9.9-15HP Outboards Service Manual, Page 80Get this manual
ELECTRICAL ELECTRIC STARTER SYSTEM
Connect 12V positive (+) to terminal (4), and (-) to terminal (3)Then, check continuity between terminal (1) and (2) when 12 is applied
Starter Motor Service
Removal
Remove engine side coversRefer to side cover Removal and Installation on p180Remove recoil starterRefer to manual starter REMOVAL on p219
004731 12 Power Applied Not Applied Continuity
1Recoil starter
Measure resistance between relay terminals (3) and (4)Starter motor relay solenoid coil resistance: 145 to 190 n